1. The Automatic Sheet Metal Punching Machine is designed with a high rigidity frame, which is welded with high-quality steel plates and treated with stress relief technology to improve the stability and reliability of the entire machine's accuracy.
2. The transmission center is aligned with the overall center of the machine to ensure the accuracy and stability of the punch press.
3. The mold adjustment accuracy can reach up to 0.01mm, which is safe, convenient, and reliable.
4. Advanced design concepts, low noise, low consumption, and energy conservation.
5. Automatic Sheet Metal Punching Machine with fully intelligent PLC control, electric mold adjustment, and overload hydraulic protection; Variable frequency adjustment and automatic oil cut-off alarm device; Electronic digital display module with high memory function, optional hydraulic locking and lifting automatic device.
|
Item |
DPA-25 |
DPA-35 |
|||
|
Model |
V |
H |
V |
H |
|
|
Capacity |
Ton |
25 |
35 |
||
|
Rated Tonnage Point |
mm |
3.2 |
1.6 |
3.2 |
1.6 |
|
Speed Changing |
s.p.m |
60~140 |
130~200 |
40~120 |
110~180 |
|
Stable Speed |
s.p.m |
110 |
85 |
||
|
Stroke |
mm |
60 |
30 |
70 |
40 |
|
Die Height |
mm |
200 |
215 |
220 |
235 |
|
Slide Adjustment |
mm |
50 |
55 |
||
|
Slide Area |
mm |
300×220×50 |
360×250×50 |
||
|
Bolster Area |
mm |
680×300×70 |
800×400×70 |
||
|
Shank Hole |
mm |
Φ38 |
Φ38 |
||
|
Main Motor |
kw.p |
2.2×4 |
3.7×4 |
||
|
Slide Adjust Device |
Manual operation |
Manual operation |
|||
|
Air Pressure |
kg/cm² |
5~6 |
5~6 |
||
|
Presses Precision |
CNS(Jls)1class |
CNS(JlS)1class |
|||
|
Presses Dimension |
mm |
930×1390×2125 |
1000×1450×2300 |
||
|
Die Cushion Capacity |
Ton |
- |
2.3 |
||
|
Stroke |
mm |
- |
50 |
||
|
Die Cushion effective area |
mm² |
- |
300×230 |
||
|
DPA-45 |
DPA-60 |
DPA-80 |
DPA-110 |
||||
|
V |
H |
V |
H |
V |
H |
V |
H |
|
45 |
60 |
80 |
110 |
||||
|
3.2 |
1.6 |
4 |
2 |
4 |
2 |
6 |
3 |
|
40~100 |
100~150 |
35~90 |
80~120 |
35~80 |
80~120 |
30~60 |
60~90 |
|
75 |
65 |
65 |
50 |
||||
|
80 |
50 |
120 |
60 |
150 |
70 |
180 |
80 |
|
250 |
265 |
310 |
340 |
340 |
380 |
360 |
410 |
|
60 |
75 |
80 |
80 |
||||
|
400×300×60 |
500×360×70 |
560×420×70 |
650×470×80 |
||||
|
850×440×80 |
900×500×80 |
1000×550×90 |
1150×600×110 |
||||
|
Φ38 |
Φ50 |
Φ50 |
Φ50 |
||||
|
5.5×4 |
5.5×4 |
7.5×4 |
11×4 |
||||
|
Manual operation |
Electric driving |
||||||
|
5~6 |
5~6 |
5~6 |
5~6 |
||||
|
CNS(JlS)1class |
|||||||
|
1040×1650×2390 |
1090×1670×2750 |
1328×1820×2980 |
1458×1970×3133 |
||||
|
2.3 |
3.6 |
3.6 |
6.3 |
||||
|
50 |
70 |
70 |
80 |
||||
|
300×230 |
350×300 |
450×310 |
500×350 |
||||
|
DPA-160 |
DPA-200 |
DPA-260 |
DPA-315 |
||||
|
V |
H |
V |
H |
V |
H |
V |
H |
|
160 |
200 |
260 |
315 |
||||
|
6 |
3 |
6 |
3 |
7 |
3.5 |
8 |
3.5 |
|
20~50 |
40~70 |
20~50 |
50~70 |
20~40 |
40~50 |
20~35 |
35~50 |
|
35 |
35 |
30 |
30 |
||||
|
200 |
90 |
200 |
100 |
250 |
150 |
250 |
150 |
|
460 |
510 |
460 |
510 |
500 |
550 |
500 |
550 |
|
100 |
110 |
120 |
120 |
||||
|
700×550×90 |
850×630×90 |
950×700×100 |
1200×700×100 |
||||
|
1250×800×140 |
1400×820×160 |
1500×840×180 |
1600×840×180 |
||||
|
Φ65 |
Φ65 |
Φ65 |
Φ70 |
||||
|
15×4 |
18.5×4 |
22×4 |
30×4 |
||||
|
Electric driving |
|||||||
|
5~6 |
5~6 |
5~6 |
5~6 |
||||
|
CNS(Jls)1class |
CNS(Jls)1class |
CNS(Jls)1class |
CNS(Jls)1class |
||||
|
1560×2390×3610 |
1790×2690×4058 |
1945×2865×4433 |
2145×2965×4500 |
||||
|
10 |
14 |
14 |
16 |
||||
|
80 |
100 |
100 |
100 |
||||
|
650×420 |
710×480 |
810×480 |
810×480 |
||||
|
Accessories |
Standard |
|
Hydraulic Over-load Protector |
● |
|
Manual Lubrication System |
● |
|
Frequency Inverter |
● |
|
Slide Adjust Device (DPA60 and below DPA60) |
● |
|
Slide Adjust Device (DPA 80 or more) |
● |
|
Die Height Indicator (DPA60 and below DPA60) |
● |
|
Die Height Indicator (DPA 80 or more) |
● |
|
Balance Device |
● |
|
Rotary Cam Switch |
● |
|
Crank Angle Indicator |
● |
|
Electric Stroke Counter |
● |
|
Air source Recepatacle |
● |
|
Against Over-run Safety Device |
● |
|
Maintenance Tool Box |
● |
|
Operation Manual |
● |
|
Accessories |
Optional |
|
Electrical Automatic Lubrication System |
○ |
|
Pneumatic Die Cusion Device |
○ |
|
Presrt Counter |
○ |
|
Presrt Counter |
○ |
|
Foot Switch |
○ |
|
Quick Die Change Device (Die Lifter,Clamp And Die Arm shift mode) |
○ |
|
Slide Knock-out Device |
○ |
|
Misfeed Detection Consent |
○ |
|
Power Supply |
○ |
|
Anti-vibration Press Mount |
○ |
|
Photo-electronic Safety Device |
○ |
|
Feeder |
○ |
|
Rack |
○ |
|
Leveler |
○ |
|
Machanism Hand |
○ |
|
Die Room Light |
○ |
How to deal with internal leakage of pneumatic control valve
Pneumatic control valve internal leakage how to deal with the pneumatic control valve internal leakage is the most obvious phenomenon is the valve closed dead. There are foreign bodies in the valve cause the valve to close the fault, mostly in the new installation of the use of the valve, such as process pipe blowing and washing, without closing the regulator before, after the cut-off valve, or without a bypass. In many cases it is necessary to remove the valve for inspection, cleaning and removal of blockage. Easy crystallization or easy to block the occasion, can change the structure of the valve to reduce the blockage phenomenon, can be straight through the single, double seat valve to sleeve valve, with a self-cleaning performance of the Angle valve.
Pneumatic control valve before and after the pressure difference is large, and the output force of the actuator is not enough, there will be internal leakage fault. Should check the reason for the large pressure difference, is the process factor, or the selection of the wrong, increase the output force of the pneumatic actuator, is a common method to improve the sealing performance, such as adjusting the working range of the spring, use the spring with small stiffness; Add a locator, adjust the air source pressure; When there is still no change, the pneumatic actuator with greater thrust can only be used.
Spool or valve seat corrosion, wear is the main cause of valve leakage in the original. Maintenance needs to repair or replace the damaged spool, valve seat, pneumatic control valve is due to cavitation wear, can be used to flow closed valve, the valve outlet is installed throttle orifice plate, to keep the downstream side pressure of the control valve more than the liquid vapor pressure, can prevent high flow rate and low pressure zone into bubbles; For large differential pressure use, two regulator valves can be used in series to distribute and limit the valve pressure drop.
Factory display


Hot Tags: automatic sheet metal punching machine, China automatic sheet metal punching machine manufacturers, suppliers, factory, Mechanical Power Press, Punch Press Machine, Pneumatic Punch Press Machine, Aluminium Punching Machine, Aluminum Punching Machine, Battery Cable Terminals







